Cost Responsibility for Interconnection Facilities and Distribution Upgrades Sample Clauses

POPULAR SAMPLE Copied 1 times
Cost Responsibility for Interconnection Facilities and Distribution Upgrades. 4.1 Interconnection Facilities 4.2 Distribution Upgrades
Cost Responsibility for Interconnection Facilities and Distribution Upgrades. 9.1. The Customer shall pay FPL for the actual cost of any and all FPL Interconnection Facilities and Distribution Upgrades, itemized in Attachment 2, required to implement this Interconnection Agreement. FPL shall provide a best estimate cost, including overheads, for the purchase and construction of FPL’s Interconnection Facilities and Distribution Upgrades required and shall provide a detailed itemization of such costs. 9.2. The Customer shall be responsible for all reasonable expenses, including overheads, associated with: i.) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities and other equipment; and ii.) operating, maintaining, repairing, and replacing FPL’s Interconnection Facilities and Distribution Upgrades. 9.3. FPL shall design, procure, construct, install and own the Interconnection Facilities and Distribution Upgrades, described in Attachment 2, required for FPL to implement this Interconnection Agreement. If FPL and the Customer agree, the Customer may construct Interconnection Facilities and Distribution Upgrades that are located on land owned by the Customer. The actual cost of Interconnection Facilities and Distribution Upgrades, including overheads, shall be directly assigned to and paid by the Customer.
Cost Responsibility for Interconnection Facilities and Distribution Upgrades. None The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The Transmission Owner shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, and the Transmission Owner. The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and (2) operating, maintaining, repairing, and replacing the Transmission Owner’s Interconnection Facilities.
Cost Responsibility for Interconnection Facilities and Distribution Upgrades. 4.1 Interconnection Facilities 4.1. 1The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in the Exhibits to this Agreement. If a Facilities Study was performed, T & D Utility shall identify its Interconnection Facilities necessary to safely interconnect the Small Generator Facility with T & D Utility's Electric Distribution System, the cost of those facilities, and the time required to build and install those facilities. 4.1. 2The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its Interconnection Equipment, and (2) operating, maintaining, repairing, and replacing T & D Utility’s Interconnection Facilities as set forth in the Exhibits to this Agreement.
Cost Responsibility for Interconnection Facilities and Distribution Upgrades. Interconnection Facilities The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in the Exhibits to this Agreement. If a Facilities Study was performed, T & D Utility shall identify its Interconnection Facilities necessary to safely interconnect the Small Generator Facility with T & D Utility's Electric Distribution System, the cost of those facilities, and the time required to build and install those facilities. The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its Interconnection Equipment, and (2) operating, maintaining, repairing, and replacing T & D Utility’s Interconnection Facilities as set forth in the Exhibits to this Agreement. Distribution Upgrades T & D Utility shall design, procure, construct, install, and own any Distribution Upgrades. The actual cost of the Distribution Upgrades, including overheads, shall be directly assigned to the Interconnection Customer.
Cost Responsibility for Interconnection Facilities and Distribution Upgrades 

Related to Cost Responsibility for Interconnection Facilities and Distribution Upgrades

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner. 4.1.2 The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties use Two-Way Interconnection Trunks for the exchange of traffic between Frontier and Onvoy, Onvoy, at its own expense, shall: 2.4.1.1 provide its own facilities to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA; and/or 2.4.1.2 obtain transport to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA (a) from a third party, or, (b) if Frontier offers such transport pursuant to a Frontier access Tariff, from Frontier. 2.4.2 Where the Parties use Two-Way Interconnection Trunks for the exchange of traffic between Frontier and Onvoy, Frontier, at its own expense, shall provide its own facilities to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA. 2.4.3 Prior to establishing any Two-Way Interconnection Trunks, Onvoy shall meet with Frontier to conduct a joint planning meeting (“Joint Planning Meeting”). At that Joint Planning Meeting, each Party shall provide to the other Party originating Centum Call Seconds (Hundred Call Seconds) information, and the Parties shall mutually agree on the appropriate initial number of End Office and Tandem Two-Way Interconnection Trunks and the interface specifications at the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA at which the Parties interconnect for the exchange of traffic. Where the Parties have agreed to convert existing One-Way Interconnection Trunks to Two-Way Interconnection Trunks, at the Joint Planning Meeting, the Parties shall also mutually agree on the conversion process and project intervals for conversion of such One-Way Interconnection Trunks to Two-Way Interconnection Trunks. 2.4.4 On a semi-annual basis, Onvoy shall submit a good faith forecast to Frontier of the number of End Office and Tandem Two-Way Interconnection Trunks that Onvoy anticipates Frontier will need to provide during the ensuing two (2) year period for the exchange of traffic between Onvoy and Frontier. Onvoy’s trunk forecasts shall conform to the Frontier CLEC trunk forecasting guidelines as in effect at that time. 2.4.5 The Parties shall meet (telephonically or in person) from time to time, as needed, to review data on End Office and Tandem Two-Way Interconnection Trunks to determine the need for new trunk groups and to plan any necessary changes in the number of Two-Way Interconnection Trunks. 2.4.6 Two-Way Interconnection Trunks shall have SS7 Common Channel Signaling. The Parties agree to utilize B8ZS and Extended Super Frame (ESF) DS1 facilities, where available. 2.4.7 With respect to End Office Two-Way Interconnection Trunks, both Parties shall use an economic Centum Call Seconds (Hundred Call Seconds) equal to five (5). Either Party may disconnect End Office Two-Way Interconnection Trunks that, based on reasonable engineering criteria and capacity constraints, are not warranted by the actual traffic volume experienced. 2.4.8 Two-Way Interconnection Trunk groups that connect to a Frontier access Tandem shall be engineered using a design blocking objective of Xxxx- Xxxxxxxxx X.005 during the average time consistent busy hour. Two-Way Interconnection Trunk groups that connect to a Frontier local Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.01 during the average time consistent busy hour. Frontier and Onvoy shall engineer Two-Way Interconnection Trunks using Telcordia Notes on the Networks SR 2275 (formerly known as BOC Notes on the LEC Networks SR-TSV-002275). 2.4.9 The performance standard for final Two-Way Interconnection Trunk groups shall be that no such Interconnection Trunk group will exceed its design blocking objective (B.005 or B.01, as applicable) for three (3) consecutive calendar traffic study months. 2.4.10 Onvoy shall determine and order the number of Two-Way Interconnection Trunks that are required to meet the applicable design blocking objective for all traffic carried on each Two-Way Interconnection Trunk group. Onvoy shall order Two-Way Interconnection Trunks by submitting ASRs to Frontier setting forth the number of Two-Way Interconnection Trunks to be installed and the requested installation dates within Frontier’s effective standard intervals or negotiated intervals, as appropriate. Onvoy shall complete ASRs in accordance with OBF Guidelines as in effect from time to time. 2.4.11 Frontier may (but shall not be obligated to) monitor Two-Way Interconnection Trunk groups using service results for the applicable design blocking objective. If Frontier observes blocking in excess of the applicable design objective on any Tandem Two-Way Interconnection Trunk group and Onvoy has not notified Frontier that it has corrected such blocking, Frontier may submit to Onvoy a Trunk Group Service Request directing Onvoy to remedy the blocking. Upon receipt of a Trunk Group Service Request, Onvoy will complete an ASR to establish or augment the End Office Two-Way Interconnection Trunk group(s), or, if mutually agreed, to augment the Tandem Two-Way Interconnection Trunk group with excessive blocking and submit the ASR to Frontier within five (5) Business Days. 2.4.12 The Parties will review all Tandem Two-Way Interconnection Trunk groups that reach a utilization level of seventy percent (70%), or greater, to determine whether those groups should be augmented. Onvoy will promptly augment all Tandem Two-Way Interconnection Trunk groups that reach a utilization level of eighty percent (80%) by submitting ASRs for additional trunks sufficient to attain a utilization level of approximately seventy percent (70%), unless the Parties agree that additional trunking is not required. For each Tandem Two- Way Interconnection Trunk group with a utilization level of less than sixty percent (60%), unless the Parties agree otherwise, Onvoy will promptly submit ASRs to disconnect a sufficient number of Interconnection Trunks to attain a utilization level of approximately sixty percent (60%) for each respective group, unless the Parties agree that the Two-Way Interconnection Trunks should not be disconnected. In the event Onvoy fails to submit an ASR for Two-Way Interconnection Trunks in conformance with this Section, Frontier may disconnect the excess Interconnection Trunks or bill (and Onvoy shall pay) for the excess Interconnection Trunks at the applicable Frontier rates. 2.4.13 Because Frontier will not be in control of when and how many Two-Way Interconnection Trunks are established between its network and Onvoy’s network, Frontier’s performance in connection with these Two-Way Interconnection Trunk groups shall not be subject to any performance measurements and remedies under this Agreement, and, except as otherwise required by Applicable Law, under any FCC or Commission approved carrier- to-carrier performance assurance guidelines or plan. 2.4.14 Onvoy will route its traffic, or traffic belonging to its Interconnected VoIP Provider Customers, to Frontier over the End Office and Tandem Two-Way Interconnection Trunks in accordance with SR-TAP-000191, including but not limited to those standards requiring that a call from Onvoy to a Frontier End Office will first be routed to the End Office Interconnection Trunk group between Onvoy and the Frontier End Office.

  • One-Way Interconnection Trunks 2.3.1 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from Onvoy to Frontier, Onvoy, at Onvoy’s own expense, shall: 2.3.1.1 provide its own facilities for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA; and/or 2.3.1.2 obtain transport for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA (a) from a third party, or, (b) if Frontier offers such transport pursuant to a Frontier access Tariff, from Frontier. 2.3.2 For each Tandem or End Office One-Way Interconnection Trunk group for delivery of traffic from Onvoy to Frontier with a utilization level of less than sixty percent (60%) for final trunk groups and eighty-five percent (85%) for high usage trunk groups, unless the Parties agree otherwise, Onvoy will promptly submit ASRs to disconnect a sufficient number of Interconnection Trunks to attain a utilization level of approximately sixty percent (60%) for all final trunk groups and eighty-five percent (85%) for all high usage trunk groups. In the event Onvoy fails to submit an ASR to disconnect One-Way Interconnection Trunks as required by this Section, Frontier may disconnect the excess Interconnection Trunks or bill (and Onvoy shall pay) for the excess Interconnection Trunks at the rates set forth in the Pricing Attachment. 2.3.3 Where the Parties use One-Way Interconnection Trunks for the delivery of traffic from Frontier to Onvoy, Frontier, at Frontier’s own expense, shall provide its own facilities for delivery of the traffic to the technically feasible Point(s) of Interconnection on Frontier’s network in a LATA.